Skip to main contentSkip to search
Episciences
Open Access Journals
Sign in(new window)
Open Plasma Science logo
Open Plasma Science
Open Plasma Science logo
Open Plasma Science
Sign in(new window)
Articles & Issues
All articlesAll volumesAuthors
About
The journal
Boards
Publish
For authorsEthical charter
Submit
Open Plasma Science logo
Journal's leaflet
|
Contact
|
Credits
eISSN 3076-1468
|
RSS
|
Atom
Episciences
Documentation
|
Acknowledgements
|
Publishing policy
Accessibility: non-compliant
|
Legal mentions
|
Privacy statement
|
Terms of use
  1. Home > Articles & Issues >
  2. Articles >
  3. Diagnostics of a Mul ...
Article

Diagnostics of a Multicusp-Assisted Inductively-Coupled Radio-Frequency Plasma Source for Plasma Immersion Ion Implantation

Moreno Joel (1), Jimenez Marilyn (1), Okerstrom Daniel (1), Bradley Michael P. (1), Couëdel Lénaïc ORCID (2) (1)
(1) Department of Physics and Engineering Physics [Saskatoon]
(2) Physique des interactions ioniques et moléculaires
Download article
Open on HAL
Submitted on
October 21, 2025
Accepted on
January 14, 2026
Published on
January 26, 2026
Last modified on
February 2, 2026
Volume 2
Volume 2
DOI
10.46298/ops.16754
License
Attribution 4.0 International (CC BY 4.0)
Indicators
815
Views
59
Downloads

Diagnostics of a Multicusp-Assisted Inductively-Coupled Radio-Frequency Plasma Source for Plasma Immersion Ion Implantation

Moreno Joel (1), Jimenez Marilyn (1), Okerstrom Daniel (1), Bradley Michael P. (1), Couëdel Lénaïc ORCID (2) (1)
(1) Department of Physics and Engineering Physics [Saskatoon]
(2) Physique des interactions ioniques et moléculaires
Abstract
In this article, we present a detailed characterisation of a multicusp-assisted inductively coupled RF plasma source for plasma immersion ion implantation (PIII). Using laser-induced fluorescence (LIF) and RF-compensated Langmuir probe diagnostics, we measured ion temperature T i and drift velocity v z in argon plasmas near an immersed electrode. The multicusp configuration enhances plasma density at low pressure, enabling stable operation down to 0.8 mTorr. Timeaveraged measurements show no detectable perturbation near the pulsed electrode, indicating full plasma recovery between high-voltage pulses. LIF-derived potential profiles match Riemann's presheath theory, and ion velocity distributions reveal acceleration consistent with sheath dynamics. These results support the use of LIF for steady-state characterisation of the bulk and presheath regions in PIII systems.
Keywords
  • [PHYS.PHYS.PHYS-PLASM-PH]Physics [physics]/Physics [physics]/Plasma Physics [physics.plasm-ph]
  • Inductively Coupled Plasma
  • Laser induced fluorescence LIF
Preview
Loading PDF preview...